Please ensure Javascript is enabled for purposes of website accessibility Skip to main content

InServe Mechanical Integrity Group

Veteran owned · Sulphur, LA · API 510 · 570 · 653
Traditional and advanced NDE

NDE integrity inspection, from a quick visual to phased array.

Visual and ultrasonic thickness testing give you useful answers at low cost. Phased array and eddy current give you answers you can’t get any other way. Our technicians are certified across both, so the method fits the question.

What it is

Why clients call us for NDE.

Most facilities need a full-service inspection firm with experience in both traditional and advanced NDE and NDT techniques. Visual inspection and ultrasonic thickness testing provide useful insight at low cost. Advanced technologies like phased array flaw detection and eddy current tube testing produce high-value reports with insight that is hard to get any other way.

That is why our technicians are certified in a broad range of techniques, and why our advanced NDE inspectors hold certifications such as QUTE, QUSE, QUPA, QUSE-PA, QUTE-TM and NRCan-NDTCB. With our partner companies there is very little we can’t offer.

Clients use our NDE work to prevent accidents and the costs that come with them, raise reliability and quality, stay in compliance, get the information needed for maintenance or repairs, and manage assets for the long term.

Advanced NDE certifications

QUTEQUSEQUPAQUSE-PAQUTE-TMNRCan-NDTCB
Methods

The NDE methods we run.

  • Visual testing (VT)
  • Magnetic particle testing (MT)
  • Dye penetrant testing (PT)
  • Ultrasonic thickness testing (UTT)
  • Automated ultrasonic thickness testing (AUT)
  • Ultrasonic shear wave flaw detection (UTSW)
  • Phased array flaw detection (PAUT)
  • Eddy current tube testing (EC)
  • Radiographic examination (X-ray)
  • Magnetic flux leakage (MFL)
  • EMAT
  • Open Vision
  • Neutron backscatter
  • Bolt inspection
  • Positive material identification (PMI)
  • Leak testing (bubble and pressure)
How a job starts

From the first call to a report you can file.

Start with a quote

Send the equipment list

Tanks, vessels, piping circuits, whatever is coming due. Nameplate photos and past reports help if you have them.

We confirm code and scope

An API certified inspector sorts out which code governs each item, the intervals and the NDE methods that fit the damage you are watching for.

Inspection on site

We schedule around operations or your turnaround. Screening methods and intelligent access cut down on craft support.

Findings and next dates

You get the findings, thickness data and recommended next inspection dates, ready for your MI program.

Questions

Common questions.

What is the difference between NDT and NDE?

They mean the same thing in practice: testing or evaluating a material without damaging it. Thickness testing of steel, flaw detection in tubes and rods, and weld inspection with ultrasonics or X-ray are all examples.

When is visual inspection enough?

Visual testing is cost effective because it needs little equipment or setup time. Inspectors use borescopes, mirrors, weld and pit gauges and illuminators, and code criteria decide whether a weld is acceptable. When the damage isn’t visible from the surface, we move to UT or advanced methods.

What is dye penetrant testing used for?

Liquid penetrant testing checks the integrity of new welds and base metal for surface-breaking flaws. It is simple to perform and a common first step on welds.